When the alarm is initiated, the console beeper will be turned on and
an alarm dial-out sequence will be initiated after the normal dial-out
delay. Both voice and digital communicator dial-outs may be used.
The voice dial-out will follow the Dial Order as specified in Set Up
Dial. The digital communicator will report the Freeze Alarm Code
to the Central Station.
Inside and outside sirens are not activated for freeze alarms (This
feature must be activated by your installer).
A Model 14A00 Outdoor Temperature Sensor is available which may
be mounted outdoors to read the outdoor temperature. The zone used
for the outdoor sensor is set up as an outdoor temperature zone type,
rather than as a programmable energy saver module zone type. When
set up this way, the corresponding auxiliary output is not dedicated to
the Model 14A00 and may be used for other purposes. Also, freeze
alarms will not be generated by the outdoor temperature.
Outdoor temperature zones have a High and Low temperature
associated with them that can be used for control purposes. An
example where the bathroom heat is turned on if the outdoor temp
goes below 60 degrees is shown in the Programming section. High
and Low temperatures are changed the same way as a PESM.
You can control appliances connected to X-10 modules (such as a
ceiling fan) using the Button feature of the Omni. For example,
the ceiling fan can be programmed to come on if the temperature goes
above the High temperature. (A programming example to set this up
is shown in the Programming section.)
High and Low setpoints for temperature zones are changed the same
way as the PESM. However, on/off control of the ceiling fan is done
from the 1 (CONTROL) menu. Use the ceiling fan's unit number to
turn it On or Off. The PESM and the ceiling fan are linked together
by a button program.
Temperature sensors can be used to signal that a temperature (in a
special room, like a greenhouse or wine cooler) has gotten too high or
too low. If the temperature in this zone goes above the High setpoint
or below the Low setpoint, the console beeper is activated (inside and
Outdoor
Temperature
Temperature Control
of Appliances
Temperature
Alarms