When the gas alarm is activated, the alarm responds exactly as
described under Burglar Alarm Activated, except:
- The console display reads,
"GAS ALARM! ZONE NAME TRIPPED"
- The interior sounder will pulse on - off - on, then an extended off
period to distinguish it from the burglar or fire alarm.
- The outside siren will pulse on - off - on, then an extended off
period to distinguish it from a burglar or fire alarm.
- The Central Station (if used) will receive a Gas Alarm signal.
The gas alarm takes priority over the burglar alarm, however, if a fire
alarm is already active, it will not override the fire alarm output.
Emergency alarm conditions can be activated through the console.
These conditions (Fire, Police And Auxiliary) are initiated with the
simultaneous depression of two key for approximately 1 second.
NOTE: The Emergency keys are always armed. The Fire and
Auxiliary emergency alarms are silenced by pressing the ' * ' key.
To cancel a Police emergency alarm you must press the OFF key
and enter your code.
Gas Alarm Activated
Emergency Keys
79