DESCRIPTION AE/LZB 119 1892 R1A
17
hours:minutes:seconds digital-type format.
Typically, this time is set and maintained at the
CEC/IMC Manager. Time update messages are
periodically sent from the CEC/IMC to all consoles
connected to it via the respective CIM serial
control data links. Therefore, all consoles’ clock
indications are synchronized to the CEC’s/IMC’s
time. Thus consistent time indications are displayed
at all consoles interconnected to the CEC/IMC.
Also, any CEC/IMC time-stamped logging
corresponds with console time displays.
Call History Panel—The call history panel—a
static display item—continuously displays the last
four (4) select calls and the last four (4) unselect
calls received by the console. Each call is indicated
on a caller-to-callee basis in a respective select or
unselect list within the panel. When an incoming
call is received, the oldest call in the respective list
scrolls off the list.
NOTE
Extended and detailed call history information is
available from three (3) separate pop-up (“general”)
dialog boxes (not show in a figure). One displays select
call history for the last forty-eight (48) callers, one
displays unselect call history for the last forty-eight
callers, and one displays call history on a per standard
communication module basis for the last twenty-four
(24) callers. See the console’s Operator’s Manual for
additional information.
Command Panels—The command panels, each
identified with a specific “menu” name, are the
GUI’s primary display items for console
user/dispatcher control via mouse/track-ball and/or
touch-screen actions. Only one is displayed
(chosen) at a time. Each command panel has fifteen
(15) buttons which are organized in a very user-
friendly and simplistic manner for quick dispatch
operating versatility. On each command panel,
most buttons activate specific console operating
functions such as module volume up/down control
or transmit to (PTT) the selected entity; these
buttons are located mostly to the right and bottom
portions of each command panel. Other buttons on
each command panel are utilized to switch to other
command panels; these buttons are located mostly
to the left and top portions of each command panel.
Many command panels such as the Main Menu
command panel and the Dispatch Menu command
panel have common buttons to reduce panel-to-
panel switching requirements during typical
dispatch operations. Other command panels such as
the Emergency Menu command panel, the Patch
Menu command panel and the Simulselect Menu
command panel group buttons which control
specific functions which console can perform; these
panels also share some common/widely used
buttons such as the volume control buttons.
User-Definable Screen (UDS) Configurator
Off-Line Program (Optional)
As previously stated, the UDS Configurator program is
a separately purchased software program which allows gen-
eration of custom screen configurations for the console ap-
plication’s graphical user interface. Generation is performed
by editing the factory-supplied screen initialization file and
then saving the edited file as required. The UDS Configura-
tor edit session utilizes a graphical user interface which ap-
proximately mirrors how display item changes will appear in
the console application. Typically, one UDS Configurator
program is purchased per CEC/IMC and the program is
shared among all consoles connected to the CEC/IMC.
Almost all screen display-related parameters can be
changed via the UDS Configurator. Examples include the
positioning of each and every display item on the screen, the
number and type of modules on each module page, the total
number of module pages (8 maximum), color settings for
nearly all display items’ elements (including most text
colors), the screen’s background color, text labels on certain
buttons such as the buttons on the page button panel and the
buttons on auxiliary I/O modules, “setup” (console user pro-
file) aliases/names, and full screen console GUI operation
enabled/disabled. Refer to the Installation and Set-Up
Manual included within this manual set for a complete over-
view of the screen-related changes possible with this pro-
gram.
For complete details on the use of the UDS Configura-
tor program, refer to its User’s Manual (AE/LZB 119 1896).
This manual is included with the UDS Configurator software
package.
Up to ten (10) different screen initialization files are
maintainable via the UDS Configurator at a given con-
sole/computer. Only one is active (utilized) when the con-
sole application is on-line. The active screen initialization
file is selected within a UDS Configurator edit session. If
done carefully, a screen initialization file may be shared
among (copied from/to) other consoles in the CEC/IMC
network system; see the UDS Configurator User’s Manual
for complete details.
Sample Screen Configurations
Generated with the UDS Configurator
The screen configuration snap-shots shown in Figure 3
thru Figure 5 were generated with the UDS Configurator.
NOTE
Seitenansicht 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 29 30