5 Installation of intraskan DC
5.3 Straight- Arm Installation:
• Remove the circlip fixed to the straight-arm guide rod using circlip pliers as shown in Figure 20 .
• Apply grease to the straight arm insertion rod and inner area of the bearing block. Mount the straight-
arm on the base unit bearing block and fix back the circlip to the straight-arm guide rod using circlip
pliers as shown in Figure 21 .
Figure 20
Figure 21
• Check and confirm the level of the straight-
arm using spirit level by rotating to all direc
tions as shown in Figure 22 . If not level, verti-
cal leveling can be done by adding shims be-
tween optional wall plate and base unit plate.
• Horizantal leveling can be done by tilting the
base unit plate.
Figure 22